Fault Detection & Diagnostics

Fault Detection & Diagnostics

Find Problems Before They Become Expensive.

Find Problems Before They Become Expensive.

Entronix continuously analyzes BAS, equipment, and operational data to identify abnormal conditions, equipment issues, and performance gaps.

Entronix fault detection view prioritizing equipment faults by severity

Your BAS Has the Data. Entronix Finds the Problems.

Building Automation Systems generate thousands of values every day. Temperatures. Commands. Setpoints. Valve positions. Fan status. Pressures. Schedules. Alarms. The challenge is that engineers cannot continuously review every point.

Entronix safely brings BAS data into the platform and evaluates it against defined operating rules. When conditions violate those rules, Entronix identifies the issue and brings it to the team's attention.

Riverside Tower · live BAS pointsRule AHU-07 matched · AHU-3Sample data

AHU-3 is commanded ON but the fan reports OFF. Rule AHU-07 opened an FDD issue at 09:14.

The result: earlier detection, faster troubleshooting, fewer hidden problems, and better equipment performance.

How Entronix FDD Works

Connect. Evaluate. Detect. Act.

  1. 01Connect

    Bring operational data from BAS platforms, equipment, meters, sensors, and other connected systems into Entronix.

  2. 02Evaluate

    Continuously compare live operating data against predefined or user-created rules.

  3. 03Detect

    Identify faults, abnormal conditions, equipment exceptions, and performance anomalies.

  4. 04Act

    Prioritize issues, notify the appropriate team, investigate the cause, and track corrective action.

Rules Built Around Your Operations

Define What “Normal” Means.

Every facility operates differently. Equipment sequences, schedules, setpoints, environmental requirements, and engineering standards vary by building and organization.

Entronix allows users to create rules around those requirements. A rule can continuously watch one or multiple data points and determine when operating conditions fall outside expected behavior.

Example

IFAHU is commanded ON
ANDfan status remains OFF
FORmore than a defined period
THENCreate an FDD issue.

Another example

IFheating valve > 50%
ANDcooling valve > 50%
THENFlag possible simultaneous heating and cooling.
The rules can reflect the way your organization believes the system should operate.

Create Your Own FDD Rules

Your Equipment. Your Standards. Your Logic.

Entronix gives engineering teams the ability to define the conditions they want the platform to monitor.

Rules may use:

  • Equipment status
  • Commands
  • Setpoints
  • Temperatures
  • Pressures
  • Flow
  • Valve position
  • Damper position
  • Electrical current
  • Runtime
  • Schedules
  • Energy consumption
  • Outdoor conditions
  • Multiple related points
Build a ruleSample data
IF
AND
FOR
Alarm handling
DELAY
EXCEPT

Flag an issue when Supply air temp > setpoint + 5°F while fan command is ON for more than 5 minutes, then wait 10 minutes before alarming, but suppress it during startup.

Define the logic once. Entronix watches it continuously.

What Entronix Can Look For

Detect Problems That Are Easy to Miss.

Examples of FDD rules may include:

  • 01Simultaneous Heating & Cooling

    Identify equipment heating and cooling at the same time.

  • 02Equipment Not Responding

    Detect when equipment is commanded ON but operating status does not confirm operation.

  • 03Sensor Problems

    Identify values that are stuck, unrealistic, or inconsistent with related sensors.

  • 04Schedule Exceptions

    Find equipment operating outside expected schedules.

  • 05Temperature Performance

    Identify systems that cannot maintain expected supply, return, or space conditions.

  • 06Valve & Damper Exceptions

    Detect commanded positions that do not produce the expected operational response.

  • 07Excessive Runtime

    Identify equipment operating longer than expected.

  • 08Short Cycling

    Detect repeated ON/OFF operation over short periods.

  • 09Abnormal Energy Use

    Identify unexpected consumption relative to equipment or operating conditions.

  • 10Performance Degradation

    Detect gradual changes that may indicate declining equipment performance.

Fault Detection Capabilities

Continuous Intelligence Across Operations.

Automated Fault Detection

Continuously evaluate connected operational data instead of relying on manual review.

Safely Connect to Existing BAS

Add Intelligence Without Replacing Your Controls.

Entronix FDD sits above existing Building Automation Systems.

The BAS continues doing what it was designed to do: control the building.

Entronix securely collects the operational information needed for monitoring, analysis, and fault detection.

This may include data from:

  • BACnet systems
  • Modbus systems
  • Building Automation Systems
  • Equipment controllers
  • IoT sensors
  • Meters
  • Entronix Core
  • Other supported data sources
Keep the control system. Add an intelligence layer above it.

From Fault to Root Cause

Give Engineers More Than an Alarm.

An alarm tells the engineer that something happened. FDD should help explain the condition. Entronix can bring together:

HighAHU-3 · Commanded ON, fan status OFFSample data
  • Started09:14 today
  • Duration22 min, ongoing
  • StatusOpen, assigned to Plant team

This allows engineers to see:

  • Which rule was violated
  • Which equipment is involved
  • What values triggered the issue
  • How long the condition existed
  • Whether the issue is recurring
  • What related points were doing
Less searching. More context. Faster troubleshooting.

Fault History

Know Whether the Problem Is New, or Keeps Coming Back.

Some operational problems occur once. Others happen every day.

Entronix keeps historical fault information so engineering teams can understand patterns over time.

AHU-7 · Simultaneous heating and coolingSample data

12 weeks · each square is one day · orange means the fault occurred

First occurrenceAug 2
Last occurrenceToday, 09:40
Frequency65 of 84 days
Avg duration3 h 10 min

Recurring fault · resolution open

Track: First occurrence, Last occurrence, Frequency, Duration, Affected equipment, Historical conditions, Recurring faults, Resolution status.

This helps teams distinguish between isolated events and systemic problems.

Prioritize What Matters

Not Every Fault Has the Same Impact.

A building can generate hundreds of potential issues.

Entronix helps teams organize and prioritize findings based on factors such as:

Pick the factors that matter to your team. The list re-ranks.

Riverside Tower · open issues by prioritySample data
  • High · AHU-3 · Commanded ON, fan status OFF10.0
  • High · AHU-7 · Simultaneous heating and cooling10.0
  • Medium · VAV 4-12 · Zone temp sensor stuck at 73.9°F8.8
  • Medium · CH-2 · Condenser water ΔT low7.5
  • Low · EF-2 · Running outside schedule7.5
  • Low · Boiler 1 · Short cycling, 14 starts per hour6.3
Engineering teams can focus first on the issues that matter most.

FDD Across Every Level

From One Piece of Equipment to the Enterprise.

  1. 01Enterprise

    See fault trends, recurring issues, and performance patterns across the organization.

  2. 02Portfolio

    Compare facilities, regions, campuses, or operating groups.

  3. 03Facility

    Understand active and historical faults within a building.

  4. 04System

    Analyze HVAC, electrical, mechanical, or other connected systems.

  5. 05Equipment

    Review individual equipment faults and operating history.

  6. 06Rule

    See exactly which condition was violated and why.

One Rule Across the Portfolio

Standardize Engineering Expectations.

A powerful advantage of a centralized FDD platform is the ability to establish common operating standards.

For example: create one rule for simultaneous heating and cooling. Then apply it to:

Define once. Monitor everywhere.

Rules + Analytics + AI

Let Technology Watch What Humans Cannot.

The foundation of Entronix FDD is continuous operational logic. Rules identify when defined conditions are violated. Analytics provide historical and performance context. AI can help engineering teams understand and summarize what the system is finding.

  1. Detect

    Continuously evaluate operational conditions.

  2. Correlate

    Connect related data points and equipment behavior.

  3. Prioritize

    Surface the problems most worthy of attention.

  4. Explain

    Summarize what happened and why it may matter.

  5. Report

    Turn faults and trends into management-ready information.

Engineers define how the system should operate. Entronix helps watch it continuously.

Turn Engineering Knowledge Into Software.

Experienced engineers know what to look for. They know that a certain temperature relationship indicates a problem. They know when a valve position does not make sense. They know when equipment behavior is abnormal.

But that knowledge often exists only in someone's experience.

In someone's experience

If the valve is wide open and the room still won't cool, something upstream is wrong.

Senior engineer, Riverside Tower

As an Entronix rule · Sample

IFcooling valve ≥ 95%
ANDzone temp > setpoint + 3°F
FOR30 minutes
THENFlag cooling capacity issue.

Watching 412 zones, 24 hours a day

That transforms engineering experience into organizational intelligence.

Why Organizations Choose Entronix FDD

  1. 01Use Existing BAS Data

    Unlock more value from data already being generated by building systems.

  2. 02Create Your Own Rules

    Monitor the conditions that matter to your facilities and engineering standards.

  3. 03Detect Problems Earlier

    Identify abnormal behavior before it becomes a larger operational issue.

  4. 04Reduce Manual Monitoring

    Let Entronix continuously review thousands of operational data points.

  5. 05Improve Troubleshooting

    Give engineers the rule, equipment, related values, trends, and history in one place.

  6. 06Standardize Across the Portfolio

    Apply common engineering rules across multiple systems and facilities.

  7. 07Build Institutional Knowledge

    Turn engineering knowledge into repeatable rules that the platform can monitor continuously.

Don't Wait for the Problem to Become Obvious.

Don't Wait for the Problem to Become Obvious.

Entronix FDD continuously evaluates BAS and operational data against the rules that define how your systems should perform.

Find faults earlier. Understand what caused them. Focus engineering teams where they can make the greatest impact.

Your rules. Your systems. Continuous intelligence.

Copyright © 2026 Entronix.io

All Rights Reserved.

Copyright © 2026 Entronix.io

All Rights Reserved.

Copyright © 2026 Entronix.io

All Rights Reserved.